Live Migration Comparison over TCP/IP, Compression, and SMB MultiChannel with Hyper-V 2012 R2

Hello Folks,

Need for speed? Well I have two Hyper-V beast clustered running on top of HP Proliant DL380p Gen8 servers with the following specs:

  • 2 Sockets, 8 Cores each @ 2.69GHz = 32 Logical processors
  • 8 X 1 Gbps NICs (leveraging Hyper-V Converged Network with Network teaming and QoS)
  • 256GB RAM
  • 2 X 400GB SSD Enterprise Mainstream

Where is the bottleneck in above specs? Sure enough the network bandwidth, we have only 8Gbps network pipe no 10GbE nor RDMA NICs 🙁

In order to measure the Live Migration speeds between different types of migration, I wrote a PowerShell script inspired by Ben Hyper-V Program Manager what he did in TechEd in the demo that does the following:

    • Configure the cluster to use 1 GbE team for Live Migration with TCP/IP
    • Live migrate a VM (time measured)
    • Configure the cluster to use 1 GbE team for Live Migration with Compression
    • Live migrate a VM (time measured)
    • Configure the cluster to use two 1 GbE NICs @ 2Gbps with SMB Multichannel Live Migration
    • Live migrate a VM (time measured)
    • Configure the cluster to use 1 GbE team for Live Migration with Compression again to Live Migrate the VM back to the original Node
    • Live migrate a VM (time measured)

Let’s get started…

1- Live Migrating a Virtual Machine with 8GB static RAM from WS2012 R2 to WS2012 R2 with TCP/IP:LVM_TCPIP

2- Live Migrating a Virtual Machine with 8GB static RAM from WS2012 R2 to WS2012 R2 with Compression

What is happening during the compression Live Migration?Compression

LVM_Compression

3- Live Migrating a Virtual Machine with 8GB static RAM from WS2012 R2 to WS2012 R2 with SMB MultiChannel 2X1Gbps 🙂

What is happening during the SMB Live Migration?SMBMultiChannel

LVM_SMB01

LVM_SMB02

What I observed during my test that:

  • TCP/IP: The network is used about 95% of 1 GbE NIC, the pipe is saturated during the migration with low CPU utilization @ 2%.
  • Compression: The network is used about 95% of 1 GbE NIC, the pipe is saturated during the migration, but the CPU utilization is higher now (as expected) @ 25% to 33%, but remember that Live Migration will switch to TCP/IP if compression is competing for resources with the host and Virtual Machines.
  • SMB Multichannel: Nearly 2 Gbps network throughput over the two standard NICs. SMB is the future 🙂

And the time taken for each Live Migration? LVM_Comparison

Enjoy your weekend!

Cheers,

Charbel

About Charbel Nemnom 325 Articles

Charbel Nemnom is a Microsoft Cloud Consultant and Technical Evangelist, totally fan of the latest’s IT platform solutions, accomplished hands-on technical professional with over 15 years of broad IT Infrastructure experience serving on and guiding technical teams to optimize performance of mission-critical enterprise systems. Excellent communicator adept at identifying business needs and bridging the gap between functional groups and technology to foster targeted and innovative IT project development. Well respected by peers through demonstrating passion for technology and performance improvement. Extensive practical knowledge of complex systems builds, network design and virtualization.

Be the first to comment